Home | Products | Representatives | Resources | SDS | Contact |
Polywater Support Page |
Model LP-3Hand-Operated |
ADVANTAGES |
---|
|
|
|
|
|
|
OPERATION
Open pail. Set pump handle to the proper ratio for your lubricant. Place LP-3 pump onto 5-gallon pail. Insert free end of hose into conduit opening, pail or jug. Move hand lever up and down to pump lubricant until it is visible at hose end. If installing cable, start pulling cable and continue moving hand lever to pump lubricant at desired flow rate. Click here to View a Short Video of the LP-3 in use.
Lubricant | Ratio at 7:1 | Ratio at 4:1 | Ratio at 2:1 | |||
---|---|---|---|---|---|---|
gal/stroke | gal/minute | gal/stroke | gal/minute | gal/stroke | gal/minute | |
Polywater® J, WJ | Not Recommended | 0.04 | 2.0 | 0.07 | 2.6 | |
Dyna-Blue® | 0.01 | 0.9 | 0.03 | 1.1 | Not Recommended | |
Polywater® PJ, WPJ | Not Recommended | Not Recommended | 0.07 | 3.2 | ||
Polywater® F, WF | Not Recommended | Not Recommended | 0.07 | 3.2 | ||
Polywater® G | 0.02 | 0.6 | 0.04 | 1.6 | Not Recommended | |
Polywater® PR | Not Recommended | Not Recommended | 0.07 | 3.2 | ||
Polywater® Plus Silicone NN | Not Recommended | Not Recommended | 0.07 | 3.2 |
Note 1: Pumping rates are approximate and vary with hand speed and hose length.
Note 2: Polywater® Plus Silicone NB does not work in this pump. The solid microspheres interfere with operation.
CLEANING
Pump clean tap water through LP-3 pump until water discharge is clear and no lubricant is apparent. Let pump containing tap water soak for 15 minutes. Run pump again with clean tap water to remove any remaining lubricant. Repeat the process as necessary. Wipe off pump and lightly spray inside with Type P7 penetrating oil. Protect from dirt with plastic bag or other cover.
Keep dirt and debris away from pump to avoid damage. Avoid running pump dry to prevent damage.
Catalog No. | Description |
---|---|
LP-3 | Hand-powered, self-priming transfer pump for cable pulling lubricants. Fits 5-gallon pails. |
View this flyer in PDF Format
View a Short Video of the LP-3 in use.
Click here to Add Your Name To Our Mail List
Click here for free Streaming Videos on cable lubrication and installation
Important Notice: The statements and information here are made in good faith based on tests and observations we believe to be reliable. However, the completeness and accuracy of the information is not guaranteed. Before using, the end-user should conduct whatever evaluations are necessary to determine that the product is suitable for the intended use. The user assumes all risks and liability in connection with such use. The statements contained herein are made in lieu of all warranties, express or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose, which warranties are hereby expressly disclaimed. American Polywater's only obligation shall be to replace such quantity of the product proven to be defective. Except for the replacement remedy, American Polywater shall not be liable for any loss, injury or damage, direct or indirect, arising from the use or the failure to properly use these products, regardless of the legal theory asserted. The foregoing may not be altered except by a written agreement by the officers of American Polywater Corporation.
This website uses third party cookies to analyze navigation and to improve the quality of the user experience. Address: 11222 60th Street N, Stillwater, MN 55082, USA Phone: +1 651 430-2270 | Fax: +1 651 430-3634 | Phone: 800 328-9384 (Toll-Free USA/Canada) General Email: Email Contact Page |